Hydroelectric power plants Lechwerke (LEW)
Building assessment, repair of the concrete structure, health and safety coordination
Historic railroad overpass
Penetration test (UV), x-ray fluorescence analysis, hardness measurement - Walpertskirchen
3D Printed House in Beckum, Germany
Consulting on structural design and construction, building authority approvals (ZiE and vBG), monitoring during construction and long-term monitoring
Galleries A96
Concrete technology, durability, planning, supervision, monitoring - Germering, Gilching
Monitoring Gänstorbrücke
Permanent monitoring of the bridge with different systems - Ulm
Monitoring Gänstorbrücke
Permanent monitoring of the bridge with different systems - Ulm
High masts Olympiaknoten
Deep impregnation - Munich
Stufenbauten Olympic Village
Repair of the concrete structure - Munich
Ducts, that were grouted with high pressures
Damage analysis, non-destructive testing of the ducts, assessment of the corrosion of the prestressing steel
Railway project Stuttgart-Ulm
Concrete technology, expert opinion on execution variants, state detection and evaluation - Stuttgart, Ilm
Goldachtal bridge
Examination of tendons - Schwindkirchen
Parking garage Unterföhring
Repair of the concrete structure - Unterföhring
Exposed aggregate concrete facade, Martha-Maria Hospital
Building assessment, non-destructive testing, life cycle management - Munich
P&R Olympiazentrum
Repair of the concrete structure - Munich
Parking garage Kastanienweg
Repair of the concrete structure, cathodic corrosion protection - Leipzig
Regional Administration Office
Building assessment for an upcoming expansion - Munich
Parking garage Arnulfstraße
Repair of the concrete structure - Munich
Parking garage Fraunhoferstraße
Repair of the concrete structure - Martinsried/Planegg
Tunnel Eching/Etterschlag, BAB A96
Condition assessment, development of a surface protection, optimisation of the life cycle management - Eching/Etterschlag
Parking garage district office
Repair of the concrete structure, cathodic corrosion protection - Traunstein
New high-rise building in Moscow
Damage analysis, non-destructive testing of reinforced concrete ceilings, concept for restauration- Moscow
Munich Airport
Concrete technology consultancy, support during the concreting - Munich
Parking garage Hufelandstraße
Repair of the concrete structure - Munich
Lead refinery Aurubis AG
Formulation of the hybrid fibre concrete, experiments for heat resistance, determination of the fibre content - Hamburg
Elementary and High School of the US Army
Evaluation of the quality of the fair-faced concrete, expert consultancy for the surface protection - Böblingen
Extension of the Deggendorf Institute of technology
Consultancy for fair-faced concrete, support during the overall measure - Deggendorf
Technical approval for wind power station segments
Technical approval (AbZ) for high performance, self-compacting concrete for manufactoring wind power station segments
Parking garage Grillparzer Straße
Cathodic corrosion protection - Munich
Parking garage Implerstraße
Repair of the concrete structure, cathodic corrosion protection - Munich
High masts Olympiaknoten
Evaluation of the risk of stress corrosion - Munich
ICE train hall
Evaluation of the risk of stress corrosions and examination of building elements - Hagen
Multi-storey car park Allianz Arena
Cathodic corrosion protection - Munich
Pinakothek der Moderne
Investigation and repair of cracks in masonry - Munich
Tunnel Mittlerer Ring Südwest
Life cycle management, concrete technology, installation of a monitoring system - Munich
Container Terminal
Corrosion monitoring - Port Said, Egypt
High performance concrete for footbridge
Concrete technology, development of a high performance concrete - Munich
Deutsches Theater, rabitz ceiling
Buidling assessment, analysis of the bearing capacity, recommendation for restauration measures - Munich
Sewer at the Landshuter Allee
Building assessment and monitoring - Munich
IR-Thermography, appartment constructions
Inspection of the window installation situation, Munich
Sectoral planning for building physics
Residental and non-residental buildings, KfW energy-efficient house 55
Residental composite construction
Building physics consultancy
Karlsplatz Stachus
Cathodic corrosion protection - Munich
University of Brixen, South Tyrol
Conrete technology consultancy - Brixen
Decoration shell of the Venus Grotto, Linderhof Palace
Support for a technical approval, building assessment, exercise tests in the laboratory - Ettal
S-Bahn station Marienhof
Concrete technology, concepts for sealing and design - Munich
Accidental damage at a road bridge
Condition assessment, concept for repair, tendering, supervision - Neuburg an der Donau
Underwater project
Expert opinion on corrosion damages, development of a restauration concept
Regensburg Cathedral
Restauration of the spires - Regensburg
University for Television and Film, museum for Egyptian art
Concrete technology, fair-faced concrete - Munich
Olympic Tower Munich
Investigation of the concrete structure, life cycle management - Munich
Railway tunnel
Condition assessment, non-destructive examination of tunnel linings, restauration concept
Seaside resort Kaltern
Concrete technology, development of a self-compacting concrete, supervision - Lake Kaltern, South Tyrol
Elephant house, Zoo Hellabrunn
Building assessment, evaluation of the risk of stress corrosion - Munich