Skip to main content

Stufenbauten Olympic Village

Repair of the concrete structure - Munich

Ducts of high prestressed concrete towers

Damage analysis, non-destructive testing of the ducts, assessment of the corrosion of the prestressing steel

Railway project Stuttgart-Ulm

Concrete technology, expert opinion on execution variants, state detection and evaluation - Stuttgart, Ilm

Goldachtal bridge

Examination of tendons - Schwindkirchen

Parking garage Unterföhring

Repair of the concrete structure - Unterföhring

Exposed aggregate concrete facade, Martha-Maria Hospital

Building assessment, non-destructive testing, life cycle management - Munich

P&R Olympiazentrum

Repair of the concrete structure - Munich

Parking garage Kastanienweg

Repair of the concrete structure, cathodic corrosion protection - Leipzig

Regional Administration Office

Building assessment for an upcoming expansion - Munich

Parking garage Arnulfstraße

Repair of the concrete structure - Munich

Parking garage Fraunhoferstraße

Repair of the concrete structure - Martinsried/Planegg

Tunnel Eching/Etterschlag, BAB A96

Condition assessment, development of a surface protection, optimisation of the life cycle management - Eching/Etterschlag

Parking garage district office

Repair of the concrete structure, cathodic corrosion protection - Traunstein

New high-rise building in Moscow

Damage analysis, non-destructive testing of reinforced concrete ceilings, concept for restauration- Moscow

Munich Airport

Concrete technology consultancy, support during the concreting - Munich

Parking garage Hufelandstraße

Repair of the concrete structure - Munich

Lead refinery Aurubis AG

Formulation of the hybrid fibre concrete, experiments for heat resistance, determination of the fibre content - Hamburg

Elementary and High School of the US Army

Evaluation of the quality of the fair-faced concrete, expert consultancy for the surface protection - Böblingen

Extension of the Deggendorf Institute of technology

Consultancy for fair-faced concrete, support during the overall measure - Deggendorf

Technical approval for wind power station segments

Technical approval (AbZ) for high performance, self-compacting concrete for manufactoring wind power station segments

Parking garage Grillparzer Straße

Cathodic corrosion protection - Munich

Parking garage Implerstraße

Repair of the concrete structure, cathodic corrosion protection - Munich

High masts Olympiaknoten

Evaluation of the risk of stress corrosion - Munich

ICE train hall

Evaluation of the risk of stress corrosions and examination of building elements - Hagen

Multi-storey car park Allianz Arena

Cathodic corrosion protection - Munich

Pinakothek der Moderne

Investigation and repair of cracks in masonry - Munich

Tunnel Mittlerer Ring Südwest

Life cycle management, concrete technology, installation of a monitoring system - Munich

Container Terminal

Corrosion monitoring - Port Said, Egypt

High performance concrete for footbridge

Concrete technology, development of a high performance concrete - Munich

Deutsches Theater, rabitz ceiling

Buidling assessment, analysis of the bearing capacity, recommendation for restauration measures - Munich

Sewer at the Landshuter Allee

Building assessment and monitoring - Munich

IR-Thermography, appartment constructions

Inspection of the window installation situation, Munich

Sectoral planning for building physics

Residental and non-residental buildings, KfW energy-efficient house 55

Residental composite construction

Building physics consultancy

Karlsplatz Stachus

Cathodic corrosion protection - Munich

University of Brixen, South Tyrol

Conrete technology consultancy - Brixen

Decoration shell of the Venus Grotto, Linderhof Palace

Support for a technical approval, building assessment, exercise tests in the laboratory - Ettal

S-Bahn station Marienhof

Concrete technology, concepts for sealing and design - Munich

Accidental damage at a road bridge

Condition assessment, concept for repair, tendering, supervision - Neuburg an der Donau

Underwater project

Expert opinion on corrosion damages, development of a restauration concept

Regensburg Cathedral

Restauration of the spires - Regensburg

University for Television and Film, museum for Egyptian art

Concrete technology, fair-faced concrete - Munich

Olympic Tower Munich

Investigation of the concrete structure, life cycle management - Munich

Railway tunnel

Condition assessment, non-destructive examination of tunnel linings, restauration concept

Seaside resort Kaltern

Concrete technology, development of a self-compacting concrete, supervision - Lake Kaltern, South Tyrol

Elephant house, Zoo Hellabrunn

Building assessment, evaluation of the risk of stress corrosion - Munich